Specification | Value |
---|---|
Number of phases | 1-Mar |
Rated frequency | 50/60Hz |
Rated input voltage | 208/230V, 460V |
Input voltage range | 208/230V ±10%, 460V ±10% |
Rated input power | 15.3kVA 13.1kW/ 14.9kVA 13.0kW 15.0kVA 13.3kW, 11.3kVA 8.4kW/ 11.2kVA 8.3kW 10.9kVA 8.1kW |
Rated input current | 42.5/37.4A 18.8A, 54.2/48.8A 23.7A |
Rated output current | 350A/250A |
Rated load voltage | 31.5V/26.5V |
Rated output current range | 30 – 350A/30 – 250A |
Rated output voltage range | 12.0 – 31.5V/12.0 – 26.5V |
Maximum no-load voltage | 71/78V 70V |
Rated duty cycle | 60% |
Number of welding conditions | 100 |
Operating temperature range | 14º F to 104º F (-10 to +40º C) |
Operating humidity range | less than 50%, 104º F (40º C), less than 90%, 68º F (20º C) |
Storage temperature range | -13º F to +131º F (-25 to +55º C) |
Storage humidity range | less than 50%, 104º F (40º C), less than 90%, 68º F (20º C) |
Dimensions (W x D x H) | 15.6 x 28.0 x 31.9 in. (395 x 710 x 810mm) |
Mass | 183 lbs (83kg) |
Rated input power for DC TIG scratch start | 12.5kVA 10.0kW 11.9kVA 10.0kW 12.3kVA 10.5kW, 8.6kVA 6.4kW 8.6kVA 6.3kW 8.9kVA 6.4kW |
Rated output current for DC TIG scratch start | 350A/250A |
Rated load voltage for DC TIG scratch start | 26.0V |
Rated output current range for DC TIG scratch start | 10 – 400A/10 – 250A |
Rated duty cycle for DC TIG scratch start | 60% |
Rated input power for DC STICK scratch start | 13.6kVA 11.2kW 13.1kVA 11.1kW 13.3kVA 11.6kW, 12.2kVA 9.2kW 12.1kVA 9.1kW 12.2kVA 9.1kW |
Rated output current for DC STICK scratch start | 300A/250A |
Rated load voltage for DC STICK scratch start | 32.0V/30.0V |
Rated output current range for DC STICK scratch start | 20 – 350A/20 – 250A |
Rated duty cycle for DC STICK scratch start | 60% |